Dataset Viewer
Auto-converted to Parquet Duplicate
image
imagewidth (px)
2.55k
14k
filename
stringlengths
7
7
markdown
stringlengths
115
5.69k
inference_info
stringclasses
1 value
001.jpg
These drawings are intended to provide an example for individuals preparing drawings for permit submittal. While every construction project is unique, the basic information a city needs in order to determine whether or not a project complies with codes and ordinances does not change. The following basic information sho...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
002.jpg
FOUNDATION & LOWER FLOOR FRAMING PLAN (SCALE: 1/4" = 1'-0" OR 1/8" = 1'-0" PREFERRED) SLAB ON GRADE NOTE REINFORCING SIZE, SPACING, & EMBEDMENT OF ANCHOR BOLTS TYP. MAX SHEET SIZE: 24" X 36"
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
003.jpg
SEAL: Sample House Street Address City, ST Zip DATE: Month Day, Year SHEET TITLE: FLOOR PLANS SHEET NUMBER: A3 (MAX SHEET SIZE: 24" X 36")
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
004.jpg
LOWER ROOF & UPPER FLOOR FRAMING PLAN (SCALE: 1/4" = 1'-0" OR 1/8" = 1'-0" PREFERRED) (MAX SHEET SIZE: 24" X 36")
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
005.jpg
SEAL: Sample House Street Address City, ST Zip DATE: Month Day, Year SHEET TITLE: ELEVATIONS SHEET NUMBER: A5 $\textcircled{1}$ SOUTH ELEVATION (SCALE: 1/4" = 1'-0" OR 1/8" = 1'-0" PREFERRED) $\textcircled{2}$ EAST ELEVATION (SCALE: 1/4" = 1'-0" OR 1/8" = 1'-0" PREFERRED) $\textcircled{3}$ NORTH ELEVATION (MAX S...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
006.jpg
GLAZING AREA % OF FLOOR VERTICAL OVERHEAD DOOR U-FACTOR CEILING VAULTED CEILING WALL ABOVE GRADE WALL INTERIOR BELOW GRADE WALL EXTERIOR BELOW GRADE FLOOR SLAB ON GRADE ## % ## ## R-### R-### R-### N/A N/A R-### R-### ROOF FINISH ROOF CONSTRUCTION TYPE ROOF PITCH INSULATION R VALUE & THICKNESS VAPOR BARRIER EXISTING ...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
007.jpg
1. SLAB ON GRADE 2. FOUNDATION DETAIL 3. GARAGE SLAB/WALL (ALTERNATE) 4. FLOOR-WALL CONNECTION 5. ROOF-WALL CONNECTION 6. POST-BASE CONNECTION 7. STAIR DETAIL 8. POST-BEAM CONNECTION 9. FACTORY-BUILT FIREPLACE 10. ROOF TRUSS-WALL CONNECTION 11. 16" MINIMUM LATERAL RESTRAINT PANEL 12. 24" MINIMUM LATERAL RESTRAINT PANEL...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
008.jpg
These drawings are intended to provide an example for individuals preparing drawings for permit submittal. While every construction project is unique, the basic information a city needs in order to determine whether or not a project complies with codes and ordinances does not change. The following basic information sho...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
009.png
REFERENCES: 1. FOR DETAILS OF PSC SLAB REFER DRG No. RD50/B-10277 (POST TENSIONED). 2. FOR DETAILS OF WEEP HOLE AND BACK FILING REFER DRG No. GM/WIS/CB/R/RC/SCD/TD/156/2020. 3. DETAILS OF ARRANGEMENT FOR FOOTPATH FOR h' type REFER DRG No.: CAO/C/CR/T/RC/SCD/TD/98 (COMP). 4. WORKING LANE / SECTION REFER DRAWING No.: CA...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
010.png
NOTES: 1. ALL DIMENSIONS ARE SHOWN IN MILLimetres UNLESS OTHERWISE SPECIFIED & LEVELS ARE SHOWN IN METRES AND THE DRAWING SHALL NOT BE SCALLED. 2. PROPOSED WORKS ARE SHOWN IN RED, EXISTING WORKS ARE SHOWN IN BLACK AND DIAMANTING WORKS ARE SHOWN IN YELLOW. 3. BACK FILM MATERIAL SHALL BE AS PER CLAUSE 7.5 OF IRS BRIDGE S...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
011.png
WEEP HOLES 100 Ø AT 1000 C/C BED LEVEL 295.143 1 IN 8 3942 4092 1:1 1500 3300 1200 600 150TH. LEVELLING COURSE 600 1200 680 450 1360 600 4890 297.143 WEEP HOLES 100 Ø AT 1000 C/C BED LEVEL 295.143 1:1 1500 3300 1200 600 150TH. LEVELLING 4110 C/S OF WING WALL @ MIN. HEIGHT OF WING WALL @ MAX. HEIGHT ING CAP...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
012.png
SPECIFICATIONS: EMPIRE CONDITION: MODERATE AS PER INCIDE WITH LATEST AAC SUPP. CASE OF CONNECTION FOR VOLVULATION CASE BE IN ACCORDANCE WITH HS CONNECTED BRIDGE CODE 2014 WHERE HS CONNECTED BRIDGE CODE IS MENTIONED. ALL WORK ARE CARRIED OUT AS PER THE FOLLOWING: 1. ALL WORK ARE CARRIED OUT AS PER THE FOLLOWING: 2. ALL...
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]
013.png
FIRST FLOOR PLAN OPEN TERRACE OPEN TO SKY 1.50M WIDE CORRIDOR ROOM 4.83x4.20 ROOM 3.60x4.20 ROOM 3.60x4.20 ROOM 3.60x4.20 ROOM 3.60x4.20 ROOM 3.60x4.20 ROOM 3.60x4.20 ROOM 3.60x4.20 ROOM 4.83x4.20
[{"model_id": "zai-org/GLM-OCR", "model_name": "GLM-OCR", "column_name": "markdown", "timestamp": "2026-02-09T04:12:23.732883", "task": "ocr", "temperature": 0.01, "top_p": 1e-05, "repetition_penalty": 1.1, "max_tokens": 16384}]

Document OCR using GLM-OCR

This dataset contains OCR results from images in minhpvo/ocr-input using GLM-OCR, a compact 0.9B OCR model achieving SOTA performance.

Processing Details

  • Source Dataset: minhpvo/ocr-input
  • Model: zai-org/GLM-OCR
  • Task: text recognition
  • Number of Samples: 13
  • Processing Time: 2.2 min
  • Processing Date: 2026-02-09 04:12 UTC

Configuration

  • Image Column: image
  • Output Column: markdown
  • Dataset Split: train
  • Batch Size: 16
  • Max Model Length: 8,192 tokens
  • Max Output Tokens: 16,384
  • Temperature: 0.01
  • Top P: 1e-05
  • GPU Memory Utilization: 80.0%

Model Information

GLM-OCR is a compact, high-performance OCR model:

  • 0.9B parameters
  • 94.62% on OmniDocBench V1.5
  • CogViT visual encoder + GLM-0.5B language decoder
  • Multi-Token Prediction (MTP) loss for efficiency
  • Multilingual: zh, en, fr, es, ru, de, ja, ko
  • MIT licensed

Dataset Structure

The dataset contains all original columns plus:

  • markdown: The extracted text in markdown format
  • inference_info: JSON list tracking all OCR models applied to this dataset

Reproduction

uv run https://huggingface.co/datasets/uv-scripts/ocr/raw/main/glm-ocr.py \
    minhpvo/ocr-input \
    <output-dataset> \
    --image-column image \
    --batch-size 16 \
    --task ocr

Generated with UV Scripts

Downloads last month
8